Home › Materials › Technical Laminates › Tracking-Resistant Epoxy Glass Laminate
Technical Laminates

Tracking-Resistant Epoxy Glass Laminate

Tracking-resistant glass-fabric epoxy laminate

Brand: ISOVAL® 10 FKB — Isovolta Group

Standards: IEC 60893 EP GC 310

Overview

Tracking-resistant epoxy glass laminates are selected for electrical insulation where contamination, humidity, surface leakage or high-voltage switching conditions create a risk of tracking. They are distinct from standard FR4 or G10 because the resin system and validated tracking performance are grade-specific. MaterialCut confirms the relevant standard, thickness and end use before quotation.

Grade-specific information

Available supplier grades

Each record below names the supplied grade, source and scope. Certifications, approvals, colours and forms apply only where stated for that specific grade.

ISOVAL® 10 FKB

Isovolta Group

Confirm with quotation

Tracking-resistant, flame-retardant epoxy glass laminate for insulating switchgear parts, rods and switching components.

Product form
Sheet
Thicknesses / diameters
1–60 mm
Formats / dimensions
2140 × 1040 mm; 2800 × 1220 mm
Colour
Dark brown
Surface / structure
Tracking-resistant and flame-retardant glass-fabric epoxy laminate

Key technical data

  • Density: approx. 2.0 g/cm³ (ISO 1183/A)
  • Flexural strength: 400 / 170 MPa at 23 / 130 °C (ISO 178)
  • CTI: 600 (IEC 60112)
  • Thermal endurance: TI 155 (IEC 216)
  • Flammability: UL 94 V-0 at >3 mm
Technical-data source: ISOVAL 10 FKB technical datasheet (Isovolta Group, 2018)

Grade data is taken from the named manufacturer source. Current MaterialCut supply, final dimensions and commercial conditions are confirmed in the quotation.

Disclaimer: The technical data and information provided on this page are for reference and general guidance purposes only. They are based on manufacturer datasheets and standard testing conditions. Material properties can vary depending on dimensions, machining, and specific application environments. MaterialCut does not guarantee the accuracy of this data for specific use cases. For exact specifications and critical applications, please consult the original manufacturer datasheets or contact our technical team.